NAVFAC Design-Build Model Request for Proposal - Fire Station

4.0 BUILDING REQUIREMENTS


NOTE: This is a hidden text note that will not print when the HIDDEN TEXT box on the Print tab under "Tools-Options" is unchecked.
 
Include a summary listing of all the program spaces and relationships.  Sections include Space Tabulation, Space Relationships, and Exterior Character.  Also enter Project title, location, and contract number information for page headers under the Header and Footer view.

4.1 Space Tabulation


NOTE:  The space area tabulation template (EXCEL file) provided here is an overall list of rooms based on the listing - Fire Station Program Spaces, Table 2-1 of the UFC.  Adjustments and deletions are to be made by the RFP editor based on information received from meetings with the activity user.  Not all spaces will be part of the programmed facility and shall be removed from the table.  If this is a Military Construction project, the area is based on the 1391 congressional funding document and cannot be exceeded.  If less gross square footage is provided, it cannot be reduced by more than 25% of the 1391 space allowance.  If reduction in programmed space is anticipated, it should be noted under this section.  All fire stations contain three (3) function areas - Maintenance & Apparatus, Administration & Training and Residential & Living.  Include the three categories and a breakdown listing of spaces included within each.

The Space Tabulation data shall be presented in an embedded EXCEL table under this heading.  An EXCEL file that can be embedded here can be found on the NAVFAC Design-Build website at:  http://www.wbdg.org/ndbm/. The files are included in Part 4 for the Standard Template and each Model Facilities-Type Template when you choose to download the .zip file of the entire template.

See attachment(s):

4.2 Space Relationships


NOTE:  Refer to Layout and Adjacencies within UFC 4-730-10 Fire Stations.  Functional and Illustrative Layout Diagrams and sample floor plans provide guidance on space relationships in facilitating the proper layout of the project.  Include bubble diagrams, adjacency matrices, and/or block diagrams that are customized and specific to the project in question.  The diagrams in the UFC shall only serve as a guideline to explain functional relationships. Include narrative that explains adjacencies and organizational concepts.  Identify if project or certain portions will not require ABA Accessibility Standards compliance.

4.3 Exterior Character


NOTE:  Include text, graphics and photos that illustrate the desired requirements for exterior appearance.  Section should address BEAP or IAP (whichever is applicable), aesthetics and historical elements (as applicable).